How to set the Measure Mode [GNSS]
Description of different GNSS Measurement Modes and How to Apply to iCON
Description
Settings for Measure Mode
can be found in the Status bar accessible from any application, except Draw/Sketching.
Status 1:

Set Measure Mode Step-by-Step
- From within the current application, tap
in the Status bar and select Measure Mode
.
A subscreen opens automatically, with the currently active measurement mode highlighted.
- Select Instant to have the current position measured and recorded immediately after pressing Measure, when back in the application. Instant is the default setting.
- Define a time period according to your needs at Averaging Time (sec):. Now select Average (time) as measurement mode. When you press Average back in the application, the instrument measures for the time period defined and record the calculated average data.
- Select Average (manual) as measurement mode. Back in the application press Start to start measuring. Press Stop to stop the measuring manually. A screen pops up showing the relevant information. You can store the calculated average data or refuse them.
- Define the number according to your needs at Averaging Measurements:. Now select Average (# of meas.) as measurement mode. When you press Average back in the application, the instrument performs the number of measurements defined and records the calculated average data.
- The software proceeds with the current application and the newly set measurement mode active.
These Measure Mode settings are relevant for the instrument used as rover.